New features, improvements and fixes: follow everything that makes electrical plan preparation simpler and more reliable.
9 November 2026 · Latest update50 published updates
✓FixRequested by users
Enter your dedicated socket circuit details (PREMIUM / PRO)
In French and Belgian projects, the generic dedicated 16 A socket now lets you choose its circuit rating and conductor size, to match the installed appliance.
✓Select the socket on the plan, then enter the rating, cable size and phase under “Circuit sizing” in circuit assignment. “Automatic” restores the proposed 20 A / 2.5 mm² sizing.
✓Your choices remain saved after regenerating circuits. Appliances without known sizing, including cooker hoods, retain their qualification fields.
✓In Belgium, incompatible rating/conductor size combinations, and sockets below 2.5 mm² produce a blocking error; a socket protected above 20 A is flagged. In France, the 20 A socket circuit limit is still checked with larger conductors, and a rating too high for the conductor size (for example 20 A on 1.5 mm²) now blocks any dedicated circuit, including in projects already saved.
✓Errors appear in equipment properties and electrical panel validation, and are included in the PDF report.
✓In Belgian single-line diagrams, the non-blocking guide for sockets protected above 20 A also checks values entered in the inspector. The circuit has an asterisk, its values appear in orange, and an explanatory legend is retained in the PDF export. This Planelico guide is not a statutory RGIE limit.
↗ImprovementRequested by users
Place a smart contactor or a power contactor
Two contactors join the Electrical distribution category, next to the day/night contactor: the remotely controlled smart contactor and the DIN-rail power contactor.
✓Smart contactor: show a contactor controlled by an app, a home automation hub or a solar diverter, for example to boost a solar water heater.
✓Power contactor: show a DIN-rail power contactor for heating, a heat pump, a pool pump or three-phase loads.
✓Type “contactor” in the library search to find all three contactors. The symbols are generic, with no brand or product reference.
✦New featurePlanelico initiative
Find Planelico video tutorials
A guide brings together 17 French-language tutorials, from importing a PDF plan to Pro features. Find it in the France and Belgium guides, the dashboard and the editor’s “Tutos vidéo” button (to the left of “Report a bug” in a cloud project). This shortcut follows the project country, even after visiting another market.
✓Browse topics by stage: first steps, Premium features, then job preparation with Pro. The plan label refers to the feature shown; the videos are free to watch.
✓Play each tutorial in the guide on demand, or open its YouTube video directly. You can also visit the YouTube Shorts, TikTok and Instagram channels.
✓The “Tutos vidéo” button opens a modal above your project: choose a topic, watch the video, then close it to return to your plan.
✓The Belgian guide explains the limits of French examples: shared editing steps should be distinguished from the standard and settings of a Belgian project.
Change a floor’s plan without losing your equipment
Has your plan changed? “Import PDF” now lets you change only the background of the current floor. Equipment, zones and wires stay in place.
✓When a plan already exists, “Import PDF” offers to change the floor’s background, add a floor or reset everything.
✓Other floors do not change. For a multi-page PDF, you choose which page to use.
✓Check the position of items if the plan’s framing changes. If the page size changes, the floor’s scale needs recalibrating.
✓In a project saved online, the previous plan remains available in save history.
✓FixRequested by users
Save history linked to the correct PDF plan
New versions retain their PDF plan so floors and their data can be restored together. Files used by save history stay protected, including after a rejected import.
✓Replacing the plan keeps the PDF used by versions in save history.
✓Restoration is refused without changing the project if the PDF is missing, its pages do not match the floors, or an older version’s original plan cannot be identified.
✓A rejected import or save error no longer directly deletes a PDF retained for save history.
✓FixRequested by users
A dedicated circuit for air conditioning, range hoods and heat pumps
You can now create a circuit for air-conditioning units, the range hood outlet, heat pump and pool equipment (heat pump, filtration, swim current), including items placed outside a room. The “incompatible families” message no longer blocks them, and the plan no longer reports an error on these circuits.
✓Wall-mounted, console, cassette and ducted air-conditioning units, the range hood outlet, heat pump (indoor and outdoor units), hydraulic module, and pool heat pumps, filtration pumps and swim current systems are suggested on a dedicated circuit. You can untick this in the inspector.
✓For air conditioning, heat pumps and pool equipment, the rating depends on the appliance installed: the circuit shows “To be sized” until you enter the rating, cable size and phase in the properties panel.
✓A range hood moved to a shared circuit is not counted among the kitchen sockets.
✦New featurePlanelico initiative
Planelico arrives in Belgium, built around the RGIE
Design your Belgian electrical installation to RGIE Book 1: annotated plan, panel, single-line diagram and tailored checks, with fifteen guides to help you step by step.
✓RGIE Book 1 rules are built in: socket circuits limited to eight outlets, main RCD, switched sockets, kitchens and EV chargers are checked, including after panel edits.
✓The Belgian single-line diagram flags undersized conductors, missing information per circuit and cables to specify (XVB, installation method), then exports to PDF.
✓Fifteen illustrated guides cover circuits, protection, wiring, panel labels, inspection documents, new builds, renovation, apartments and quote requests, with downloadable Belgian sample PDFs.
✓Home, pricing, account and payment pages stay in the Belgian market, with Belgian sample reports, labels and single-line diagrams.
Move the plan with a simple drag, close a zone by clicking its first point, and get symbols of consistent size, with or without a label underneath.
✓Click an empty part of the plan and drag to move it: the “Pan” button is gone. Holding the space bar and middle-clicking still work.
✓Drawing a zone no longer requires choosing a number of points: click the first point to close it, once three points are placed.
✓The plan keeps the full height of the screen when you zoom out or move it, without being cut off at the bottom.
✓Symbols with a label (oven, washing machine, 20A, USB, heat pump…) are now the same size as the others on the plan, with the label below and clear of the drawing, including in the PDF export.
✓The plans on the Pricing page are wider and easier to compare.
✦New featurePlanelico initiative
Single-line diagram generated from your panel (French projects)
For projects in France, Pro now draws the distribution diagram from the generated panel. You complete it with what is actually installed, every value is checked against NF C 15-100, and the PDF is ready to print.
✓Available for projects in France (NF C 15-100) with the Pro plan.
✓In the panel window, “Single-line diagram” draws the main breaker, RCDs and every circuit with its rating, cable size and the symbols of the equipment on your plan. Large panels continue across several landscape A4 pages.
✓Click a circuit or an RCD on the diagram to enter what is actually installed: rating, curve, poles, breaking capacity, cable type, size, fire class and installation method.
✓Every value is checked against NF C 15-100 and a non-compliant one is shown in red, with an explanation. Missing details stay orange and generator proposals stay blue until you confirm them.
✓FixPlanelico initiative
More precise electrical checks for your project’s country
Checks now distinguish electrical protection requirements from design guidelines more clearly. The preview and PDF report explain the limits of the UK and AU/NZ standards review.
✓In the US, lighting circuits are checked against wire size and breaker rating: 14 AWG up to 15 A and 12 AWG up to 20 A. A 20 A breaker on 14 AWG is flagged as a blocking issue.
✓An unknown project standard displays a warning and prevents generation of a replacement electrical panel using another country’s rules.
✓In the UK, floor area, point counts and the eight-circuits-per-RCD guideline are distinguished from protection requirements; exceeding them remains a non-blocking warning.
✓The UK model remains based on A3:2024 and requires an A4:2026 review. AS/NZS 3000:2018 profiles flag that amendments A1–A3 have not received a consolidated review; these warnings appear in the preview and PDF report.
✓UK content distinguishes electrical recommendations from requirements more clearly, and the Australian and New Zealand launch documentation has been corrected.
✓The library, favourites and recent items respect the selected country. Navigation back to projects and shared-plan links preserve your market more reliably; version history, navigation and page language follow your interface language.
✓In quotes, categories and remove buttons use your interface language.
✦New featureRequested by users
Reset your password from the sign-in page
Use “Forgot password?” to receive an email and choose a new password without knowing your old one. This also works if you normally sign in with Google.
✓On the sign-in page, enter your account email address and select “Send reset email”. The flow is available in French and English on every plan.
✓Open the link in the browser you used to request it, then enter and confirm your new password. If the link is invalid or has expired, you can request another email.
✓Reset links that return to the homepage are automatically directed to the form. Expired links display instructions for requesting a new one.
✦New featurePlanelico initiative
Planelico is now available in Australia and New Zealand: AS/NZS 3000 and switchboard
Australian and New Zealand projects follow AS/NZS 3000:2018: power point and lighting circuits, a switchboard with RCDs, TPS cables, and prices and quotes in A$ or NZ$ with GST. The site, guides and documents adapt to your country.
✓Two new markets: /au for Australia and /nz for New Zealand. You land on yours automatically, and the country selector at the top of the page lets you switch. Wording follows local usage: power point, switchboard, RCD.
✓AS/NZS 3000 circuits: power points on 2.5 mm² radial circuits at 20 A (up to 20 points) or 16 A, lighting in 1.5 mm² at 10 A (up to 20 points). A dedicated circuit is recommended for a 20 A oven; 32 A cooking stays on its own circuit.
✓Switchboard: 30 mA type A RCDs, at least two, no more than three circuits per RCD, with lighting split across RCDs so it never depends on a single one. In New Zealand, the EV charger gets a type B RCD, a circuit of at least 32 A and an isolating switch.
✓Rooms with no equipment are flagged in the generation preview and the PDF report notes, without blocking: you can continue if they are intentionally empty. Exceeding an informative capacity guideline produces a non-blocking warning.
✓Prices include GST: Premium at A$39.90 or NZ$49.90, Pro at A$19.90 or NZ$24.90 per month. An existing AUD or NZD billing currency is preserved, and checkout shows the amount and currency charged.
✓Quotes and invoices (Pro) with the country’s GST (10 % in AU, 15 % in NZ), line templates specific to each country (certificate of compliance in AU, CoC and ESC in NZ), and business fields for licence / ABN in AU and NZBN / GST in NZ.
✓Guides, terms of use and privacy policy adapted to each country.
Planelico is now available in the US: NEC 2023 and load center
US projects follow the 2023 NEC: required circuits, a load center with GFCI and AFCI breakers, imperial units, and estimates in dollars with sales tax. The site also adapts to your country without asking.
✓One site per market: planelico.com in France, /uk in the United Kingdom, /us in the United States. You land on yours automatically, and the country selector at the top of the page lets you switch.
✓NEC 2023 circuits: 20 A / 12 AWG general-purpose circuits (or 15 A / 14 AWG), lighting and receptacles on the same circuits, two small-appliance circuits for the kitchen and dining room, and 20 A circuits of their own for the laundry, bathrooms and garage.
✓Load center: each breaker carries its own protection (GFCI, AFCI or dual function) based on the rooms and appliances; 240 V circuits for the range, dryer, water heater and EV charger (sized at 125 %) take two spaces.
✓Presence checks: a receptacle in every room that needs one, switched lighting, front and back outdoor receptacles for a house.
✓Imperial units: areas in sq ft, dimensions and heights in feet and inches, wire sizes in AWG, NM-B cables and lengths in feet.
✓Estimates and invoices (Pro) in US dollars, with a free sales tax rate (labor can be non-taxable), license number and US wording.
Every project now follows its own wiring standard: BS 7671 in the UK, NF C 15-100 in France. Circuits, consumer unit, symbols, exports, quotes and invoices all match the country of the job.
✓Your country is detected automatically and applies to your new projects; you can change it at any time in “My account”. It is independent of the language: a French project can be prepared in English. Existing projects stay on NF C 15-100.
✓UK socket circuits: 32 A ring final in 2.5 mm² (up to 100 m² served), or 32 A radial in 4 mm² (75 m²) and 20 A radial in 2.5 mm² (50 m²). Capacity is counted by floor area served, not by the number of sockets.
✓Kitchen on its own ring, lighting on 6 A (up to 13 points), 30 mA type A RCDs, washing machine and dishwasher on the ring, cooker and electric shower on their own 45 A circuit.
✓New UK-only items: 45 A cooker control unit, electric shower, immersion heater, shaver socket and fused spur (FCU).
✓UK conventions across the project: circuit references (SKT, KIT, LTG, DED, RCD), twin & earth cables, consumer unit report and labels, in the language of your choice.
✓Quotes and invoices (Pro) in pounds sterling, with UK VAT (20, 5 or 0%), your company number and UK wording. A quote follows the project country, and you can pick another one.
Labels shown on the plan, plan opacity and a new double socket symbol
Name your devices and show those names right on the plan, lighten the background plan so your symbols stand out, and enjoy a clearer double socket symbol.
✓New “Show labels” button in the toolbar: the label you enter for a device (for example “Hall detector”) appears under its symbol, just like in the PDF export. Hidden by default.
✓New “Plan opacity” setting (10 to 100%), saved per floor and applied to the PDF export too: the background plan fades while your symbols, wires and zones stay crisp.
✓On small screens, both settings are available in the toolbar “…” menu.
✓The double socket symbol has been redrawn to match the triple socket: two outlets in one box, identical on the plan and in the PDF.
✦New featurePlanelico initiative
Printable consumer unit labels (PRO)
Generate your enclosure labels in one click, at the exact size of your label holders, from the panel computed by Planelico.
✓New “Export labels” button in the electrical panel window, available with the PRO plan.
✓Choose the label holder height (10 to 50 mm) and the module width (17.5 or 18 mm), with a live preview.
✓Each label shows the circuit reference, its description, the breaker rating and the conductor size.
✓Your plan symbols can illustrate each circuit; the description can also be hidden for cleaner labels.
✓Strips print at actual size, with a scale ruler and crop marks, and are split without ever cutting through a device.
✓A circuit directory to stick inside the enclosure door is added at the end of the document.
Premium and Pro members can now create circuits from the plan, freely assign devices, and instantly visualize each network.
✓Create a circuit without generating an automatic proposal first, then customize its reference and name.
✓Add or remove several devices and preserve edited circuits when generating a new automatic proposal.
✓The global selector highlights circuit devices and wires, dims the rest of the plan, and displays a stable color and circuit reference.
✓Generate native circuit wires and regenerate them whenever a change makes their route outdated.
✓Capacity overruns, incompatible equipment, and incomplete circuits are reported immediately.
✓Deletion explains its consequences before confirmation, while PDF exports reuse the references and colors shown in the editor.
✓This feature is available to Premium and Pro plans only.
↗ImprovementRequested by users
Multiple selection for devices and wires
Objects close to a wire are now easier to select, and multiple devices or wires can be edited together.
✓A device now takes priority when it sits beneath a wire, while the wire remains easy to select elsewhere on the plan.
✓Hold Cmd, Ctrl or Shift while clicking to add devices or wires to or remove them from the selection.
✓Selected devices can be moved or deleted together.
✓Layer, label, size, rotation, color, note, mounting height and compatible setting changes apply to the entire selection.
✓Selected wires can be deleted together and share the same layer, color or label settings.
✓A bulk action can be reverted in one step with the usual undo command.
✦New featureRequested by users
Custom colors for wire connections
Each wire can now use its own color or automatically inherit the color set for its layer.
✓A quick palette and a free color picker are available in every wire’s properties.
✓The selected color can be set as the layer default, including for new wires created in that layer.
✓A customized wire can return to its layer color at any time.
✓Colors are preserved in the editor, shared links, and PDF exports.
✓FixPlanelico initiative
More reliable new-floor imports
Adding a floor now detects unreadable or incompatible PDFs before changing the project.
✓The PDF selected as the floor plan is analyzed and validated before it is added to the project.
✓A clear message explains how to re-save an incompatible file so it can be imported.
✓When a PDF contains several pages, the page used for the new floor can now be selected from its preview.
✓If the import fails, the project’s existing PDF and floors remain unchanged.
↗ImprovementRequested by users
Every object can now be moved to another layer
The layer assigned to a device, zone or wire is visible in its properties and can be corrected directly.
✓A new “Layer” selector is available in the properties of devices, zones and wires.
✓Hidden or locked layers are identified before the change so an object does not appear to vanish or unexpectedly become immovable.
✓When a device or zone changes layer, room assignments are recalculated automatically.
✓Every transfer can be reverted with the usual undo command.
↗ImprovementRequested by users
Circuit labels can be shown on demand
Each wire now lets you show or hide its circuit label without deleting its content.
✓The setting is available in the wire properties, below the label field.
✓A hidden label remains saved and can be shown again at any time.
✓The choice applies to both the editor and PDF export without changing wire selection.
✦New featureRequested by users
Zone resizing and angle measurements
Zone edges can now be stretched directly, with optional measurements for every interior angle.
✓A new handle in the middle of each edge moves both endpoints together, making it quick to turn a square into a rectangle.
✓Vertex handles remain available for precise single-point adjustments.
✓The “Show angles on the plan” option adds every interior angle measurement to the editor and PDF export.
✓FixRequested by users
More reliable equipment selection and placement
Symbols can now be selected and placed accurately from the catalogue, favourites and recent equipment.
✓The same equipment remains draggable everywhere, even when it appears in its category, favourites and recent equipment at the same time.
✓Sidebar labels are no longer selected accidentally while dragging.
✓The symbol preview is centred under the pointer and placement follows its exact horizontal and vertical position, even after scrolling the sidebar.
✦New featureRequested by users
Plan dimensions and cable takeoff for Pros
Add your own dimensions and mounting heights, then estimate cable lengths using the routes actually planned for the job.
✓Create free-form dimensions or use one as a reference to set the plan scale, with a custom colour and optional label display.
✓Set a ceiling height for every floor and a mounting height for each device, with dedicated PDF pages for floor dimensions and mounting heights.
✓The Pro cable takeoff considers the source panel, ceiling, floor, wall-chase or service-void routes, direct or wall-following paths, and floor crossings.
✓Detours, site allowance and heights can be adjusted before viewing totals by cable type and the detail for every circuit.
✓The estimate can be saved with the project and included in or excluded from the PDF export using a dedicated option.
✦New featurePlanelico initiative
Three new guides for planning a home electrical installation
New-build planning, electrical panel PDFs and single-line diagrams now have illustrated guides in both English and French.
✓A visual walkthrough shows how to turn an architect plan into an electrical package ready for contractor quotations.
✓A worked example explains circuit generation, panel organisation and the pages included in the exported PDF.
✓The guides clearly distinguish floor-plan layouts, single-line diagrams and panel diagrams, including their limits and required professional validation.